KC Certification Series (RRA) | Registration of Conformity
![]() |
| KC Certification RRA Conformity Registration Korea overview |
Registration of Conformity
Conformity Registration is one of the
approval types under the Radio Research Agency (RRA) Conformity Assessment
Scheme. It applies to broadcasting and communication equipment that presents a
relatively lower risk of radio interference and electromagnetic hazards than
equipment subject to Conformity Certification. It is a mandatory certification
scheme requiring registration through testing conducted by designated test
laboratories.
1. Target Devices
ISM products using high frequency, audio/video
products (TV, Amplifier, CCTV camera), household appliances (vacuum
cleaner, washing machine, electric oven, mixer, air purifier), ITE products
(computers and internal components (HDD, mainboard), keyboard and mouse) and office
products,
Wi-Fi & BT products (certification or registration), RFID
devices (433MHz & 13.56MHz), low-power wireless devices, wired
equipment (terminal equipment (telephone, fax machine, modem), key phone
system), lift, firefighting products, AC adapter (or
battery charger), electric bicycle, etc.
2. Key Process
• Testing
Tested by designated test laboratories (including
Korea-MRA laboratories in the USA and FTA laboratories in Europe)
• Review
Review by RRA for 1 working day
3. Required Documents
Documents Submitted to RRA
• Application Form (electronic method)
• Conformity Confirmation Letter
• POA (Power of Attorney)
Documents to be retained by the local
representative (not required to be submitted to RRA)
• Conformity Confirmation Letter
• POA (Power of Attorney)
• Test Reports
• External Drawing or Photos
- Clearly showing the front and rear sides of the product,
connection interfaces, and label
• Components/Parts Placement (Layout) Drawing
or Photos
- Possible to see part number and/or specifications
• Schematics - not required for equipment
subject to EMC requirements only
• User Manual (English is ok) - Class A
equipment shall include following information.
“This device has been evaluated for use in a work environment. Use in a home environment may cause radio interference.”
4. Labeling Requirements
The following information shall be
indicated on the product or its packaging
• KC Mark
• Product Name
• Model Name
• KC ID (e.g., R-R-Company Code-Product
Code)
• Applicant (Certificate Holder) Name
• Manufacturing Date (year and month or Lot
number composed of year and month of manufacture)
GCA Korea provides expert support for global companies navigating Korea’s regulatory requirements, including KC Certification.